Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Clin Biochem ; 43(Pt 1): 23-30, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16390606

RESUMO

BACKGROUND: Clinical demand for quick, cheap, precise and accurate 25-hydroxyvitamin D (25(OH)D) results has led to the development of a variety of assay methods. Lack of standardization of these methods has resulted in inter-method disagreement and challenged whether current assays recognize 25(OH)D2 and 25(OH)D3 equally. METHODS: We studied 172 patient samples from hip fracture cases using DiaSorin (DS) and IDS radioimmunoassays and the Nichols Advantage-automated protein binding assay (NA-CLPBA) in comparison to high-performance liquid chromatography (HPLC). 52 patient samples were analysed before and after three months treatment with 1000 IU of daily ergocalciferol (vitamin D2). RESULTS: Linear regression analysis in pre-treatment samples demonstrated a positive Y-intercept for each immunoassay compared with HPLC, and a slope that varied from 0.64 (IDS) to 0.97 (DS, NA-CLPBA). Bland Altman analysis demonstrated that all the three assays had a proportional positive bias relative to HPLC at values from 20 to 50 nmol/L. Regression analysis of post-treatment samples demonstrated a slope that was not significantly different from zero for the IDS and NA-CLPBA and 0.2 for the DS method, with a positive intercept for all assays of between 8 and 22, indicating less than 50% of 25(OH)D2 measured by HPLC was detected. CONCLUSIONS: These results demonstrate the need for assay-specific decision limits for 25(OH)D3 in order to define appropriate thresholds for treatment institution. Treatment with vitamin D2 may not be accurately monitored with any of the three commercial assays studied. Clinicians and biochemists who continue to use 25(OH)D assays need to be urgently informed of these issues.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida de Alta Pressão/métodos , 25-Hidroxivitamina D 2/metabolismo , Calcifediol/metabolismo , Fraturas do Quadril/sangue , Fraturas do Quadril/tratamento farmacológico , Humanos , Sensibilidade e Especificidade
2.
Ann Clin Biochem ; 41(Pt 2): 149-54, 2004 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15025807

RESUMO

BACKGROUND: Following the introduction of two-site immunometric assays for parathyroid hormone (PTH), the expectation of good inter-assay agreement has not been fulfilled. The reasons for this may include differences in standardization as well as fragment recognition between the assays. METHODS: PTH values for healthy individuals, patients with renal failure and patients with normal renal function and elevated parathyroid hormone (hPTH) were compared using two commercial two-site immunochemiluminometric assays (Bayer Magic-lite and DPC Immulite 2000). RESULTS: Immulite results had a mean value 50.4% greater than the corresponding Magic-lite values for the whole study population with individual values ranging from 17.5% below to 118.3% above the corresponding Magic-lite value. There was no significant difference in inter-assay bias between patients with renal failure and those with normal renal function, suggesting that variable cross-reactivity with circulating disease-specific PTH fragments was not the primary cause of the observed discrepancy. Cross-reactivity with the synthetic fragment hPTH (7-84) was 34+/-5% for Magic-lite and 62+/-2% for Immulite. We also studied the stability of synthetic hPTH on storage. CONCLUSION: The instability of synthetic hPTH over extended storage periods may affect primary standard material. The consistent inter-assay differences and the over-recovery observed in external quality assessment programmes for the Immulite assay may have best been explained by differences in calibration and the relative cross-reactivities and/or kinetics of the two assay systems for specific parathyroid fragments.


Assuntos
Falência Renal Crônica/sangue , Hormônio Paratireóideo/sangue , Humanos , Imunoensaio/métodos , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Projetos de Pesquisa/normas , Sensibilidade e Especificidade
4.
Clin Chem ; 33(4): 622-4, 1987 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3829411

RESUMO

A 74-year-old man with myxedema and hypothermia had increased activities in plasma of creatine kinase (CK; EC 2.7.3.2), aspartate aminotransferase (AST; EC 2.6.1.1), and lactate dehydrogenase (LD; EC 1.1.1.27) and increased proportions of CK-MB (up to 20% of total CK) and LD1 isoenzymes, but no clinical or investigational evidence of associated myocardial infarction. This case illustrates that plasma enzyme activity and isoenzyme profiles in such clinical settings should be interpreted with caution, because increases in CK-MB and LD1 may relate to myxedema coma or hypothermia (or both) rather than to myocardial infarction.


Assuntos
Coma/enzimologia , Miocárdio/enzimologia , Mixedema/enzimologia , Idoso , Aspartato Aminotransferases/sangue , Coma/diagnóstico , Creatina Quinase/sangue , Diagnóstico Diferencial , Humanos , Hipotermia/diagnóstico , Hipotermia/enzimologia , Isoenzimas , L-Lactato Desidrogenase/sangue , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/enzimologia
5.
Med J Aust ; 1(5): 240-1, 1981 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-7231314

RESUMO

Weight loss of more than 2 kg under the guidance of a trained nurse was achieved over a 12-month period in 38% of overweight hospital and transport workers. Males over 50 were the subgroup most successful in losing weight. Weight loss achieved by older males with an "off-hand" as compared with an "energetic" approach was similar up until nine months, after which the "energetic" approach was more effective. Females on an "energetic" diet were successful up until nine months only. The "off-hand" approach is acceptable to more people and is less time-consuming. It should therefore be seriously considered by a public health authority which seeks to promote weight reduction in the general community.


Assuntos
Peso Corporal , Dieta Redutora , Adulto , Fatores Etários , Aconselhamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...